CWC FILLING FROM WDS TANKS USING COMPRESSOR
|
| 1 |
Caution: To avoid creating or propagating CWC inlet (outlet) fitting cracks, CWCs should be manipulated using side handles and not the inlet hose
|
| 2 |
Check with MCC-H for S/N of CWC and US/RSA B Hose to use
|
| 3 |
Check with MCC-H WCP selection
|
| 4 |
Check WPO is OFF
|
| 5 |
Retrieve from Russian Segment:
- Compressor
- Compressor air cable, power cable, grounding cable
- Pressurization adapter
|
| 6 |
Retrieve from American Segment:
- Empty CWC
- Mineral syringe kit
- Silver biocide syringe kit
- ACTEX Unit
- Yellow/Red QD Adapter
- Hose Adapter
- US/RSA B Hose
|
| 7 |
Configure equipment per diagram
|
| 8 |
On MCC-M GO record estimated offload time
|
| 9 |
Check with MCC-H if the CWC should be prepared for potable water or technical water
Note: Potable water has both silver biocide and minerals added. Minerals are always added first.
Technical water has only silver biocide added.
|
| 10 |
Check potable label on WCP
|
| 11 |
Open cabin air valve
Open liquid valve
|
| 12 |
Set WPO ON
|
| 13 |
Note: When the CWC is in process of filling, do not squeeze it
|
| 14 |
Set compressor pressure to 0,2
|
| 15 |
Set compressor to ON
|
| 16 |
Note: If the compressor operates continuously for 30 min press OFF then ON again
|
| 17 |
If minerals are required:
- Remove cap from mineral syringe
- Remove cap from injection port
- Install syringe
- Open valve on injection port
- Inject solution
- Fill syringe with water and re-inject
- Close valve on injection port
- Remove syringe and stow it
|
| 18 |
To inject silver biocide:
- Remove cap from silver biocide syringe
- Remove cap from injection port
- Install syringe
- Open valve on injection port
- Inject solution
- Fill syringe with water and re-Inject
- Close valve on injection port
- Remove syringe and stow it
|
| 19 |
Fill CWC for estimated offload time
|
| 20 |
Close liquid valve
|
| 21 |
Set compressor to OFF
|
| 22 |
Disconnect compressor hose from pressurization adapter
|
| 23 |
After pressure from water tank is released, close cabin air valve
|
| 24 |
Set WPO to OFF
|
| 25 |
Disassemble the equipment
|
| 26 |
Label CWC as required
Report to MCC-H
|